Single Outlet Mist Nozzle is identified in the catalogue under Irrigation fogger, with the recorded role “water-distribution component”. The page is structured for rapid model, variant and specification verification before an enquiry is prepared. Printed catalogue model references include MJ10A, MJ10B; use the technical matrix to keep each code with its own values.
Catalogue facts for this item
The resolved source fields include Spraying radius, Working pressure, MJ10A — Diameter, MJ10A — Discharge, MJ10B — Diameter. Values and units below are transcribed from the reviewed catalogue record.
| Catalogue field | Recorded value |
|---|
| Spraying radius | 1 m |
|---|
| Working pressure | 2-3 bar |
|---|
| MJ10A — Diameter | 0.8 mm |
|---|
| MJ10A — Discharge | 12 L/h |
|---|
| MJ10B — Diameter | 0.6 mm |
|---|
| MJ10B — Discharge | 8 L/h |
|---|
| Catalogue Page 5 Configuration — 0.5 mm / 7 L/h — Diameter | 0.5 mm |
|---|
| Catalogue Page 5 Configuration — 0.5 mm / 7 L/h — Discharge | 7 L/h |
|---|
The source distinguishes 3 technical variants, including MJ10A, MJ10B, Catalogue Page 5 Configuration — 0.5 mm / 7 L/h. The complete matrix remains the authority for row-level comparison. The table contains source-backed values only. Project limits and compatibility still need to be checked against the complete system.
How to select the correct variant
Compare every listed inlet or connection, pressure, discharge, nozzle and spraying-radius value with the hydraulic design. Use the technical variant row that matches the required duty point; a similar product shape is not evidence of equal performance.
Use the catalogue table as a comparison checklist and document every assumption outside it for supplier review before ordering.
Planning installation and first use
Confirm upstream filtration, lateral spacing, mounting orientation and available pressure before installation. Flush the line first, fit the specified connection without forcing it, and test one representative zone while observing the catalogue operating values.
Photograph the installed reference and record the chosen technical row after the test; this reduces ambiguity during future service.
Inspection and maintenance guidance
Inspect the nozzle or water path for deposits, check rotation or movement only where that feature is shown, and compare field discharge with the selected catalogue row. Clean with a method compatible with the actual component and replace damaged parts rather than enlarging an orifice.
Separate cleaning, adjustment and replacement decisions in the service record so the next inspection can evaluate what changed.
Information needed for product confirmation
For a precise enquiry, state the product name Single Outlet Mist Nozzle, reference MJ10A, required quantity, destination, selected technical row and the project values that must be confirmed. Include the recorded comparison point Spraying radius: 1 m.
Use the Irrigation fogger category to compare related product types and maintain a clear internal path from category research to this specification page. A concise schedule of codes, quantities and open questions gives both engineering and procurement teams an auditable basis for review.