Lock Ring Offtake Valve is catalogued under Bypass valve for irrigation flow-control component duties. The description keeps recorded technical data separate from selection advice, allowing the exact item or variant to be checked first. Printed catalogue model references include V25L1, V28L1, V32L1, V40LIRRINEX, V50LIRRINEX; use the technical matrix to keep each code with its own values.
Catalogue facts for this item
The resolved source fields include V25L1 — Catalogue size, V28L1 — Catalogue size, V32L1 — Catalogue size, V40LIRRINEX — Catalogue size, V50LIRRINEX — Catalogue size. Values and units below are transcribed from the reviewed catalogue record.
| Catalogue field | Recorded value |
|---|
| V25L1 — Catalogue size | 25 |
|---|
| V28L1 — Catalogue size | 28 |
|---|
| V32L1 — Catalogue size | 32 |
|---|
| V40LIRRINEX — Catalogue size | 40 |
|---|
| V50LIRRINEX — Catalogue size | 50 |
|---|
| V60LIRRINEX — Catalogue size | 63 |
|---|
The source distinguishes 6 technical variants, including V25L1, V28L1, V32L1, V40LIRRINEX, V50LIRRINEX. The complete matrix remains the authority for row-level comparison. The table contains source-backed values only. Project limits and compatibility still need to be checked against the complete system.
How to select the correct variant
Compare connection size, valve form, operating method and every catalogue pressure or flow value with the system requirement. Where variants differ, keep the selected code and its row together throughout design, purchasing and installation.
Start with the duty point, then eliminate variants whose recorded fields do not match. This prevents a familiar name from overriding the actual technical row.
Installation checks for the project
Confirm flow direction only from a verified marking or document, support adjacent pipework and keep debris out of the sealing path. Commission the valve gradually and check the assembled section under the project test procedure.
Photograph the installed reference and record the chosen technical row after the test; this reduces ambiguity during future service.
Maintenance points to plan
Cycle or inspect the operating mechanism according to site practice, watch for leakage and verify that control parts move without forcing. Record the exact variant before replacing an actuator, seal or complete valve.
Separate cleaning, adjustment and replacement decisions in the service record so the next inspection can evaluate what changed.
Preparing an accurate B2B enquiry
For a precise enquiry, state the product name Lock Ring Offtake Valve, reference V25L1, required quantity, destination, selected technical row and the project values that must be confirmed. Include the recorded comparison point V25L1 — Catalogue size: 25.
Use the Bypass valve category to compare related product types and maintain a clear internal path from category research to this specification page. Attach drawings or connection photographs when they affect identification, and ask for a written response to every open compatibility point.